ADSFIELDINSPECTIONPRODUCT TYPE
MPHAATSR MPH cycle number consistencyCompare the cycle with numbers in product name. Warning setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
MPHAATSR MPH phase number consistencyCompare the phase with numbers in product name. Warning setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
MPHAATSR MPH product error flagCheck the product error flag. Warning if set to 1ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
MPHAATSR MPH product size consistencyCompare the size reported in MPH with the actual product size. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
MPHAATSR MPH relative orbit consitencyTest if relative orbit number is less than 501. Warning setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
MPHAATSR MPH sensing time consistencyCheck if sensing_start time is LT sensing_stop time. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Latitude values consistencyCompare if the latitudes values are into the range [-90; 90]. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Longitude values consistencyCompare if the latitudes values are into the range [-180; 180]. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 0.87m MAX tempCheck on 0.87µ MAX temp. Test passed if the temperature is LT 273K and GT 255K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 0.87m MIN tempCheck on 0.87µ MIN temp. Test passed if the temperature is LT 273K and GT 255K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 1.6m MAX tempCheck on 1.6µ MAX temp. Test passed if the temperature is LT 85K and GT 75K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 1.6m MIN tempCheck on 1.6µ MIN temp. Test passed if the temperature is LT 85K and GT 75K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 11m MAX tempCheck on 11µ MAX temp. Test passed if the temperature is LT 85K and GT 75K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 11m MIN tempCheck on 11µ MIN temp. Test passed if the temperature is LT 85K and GT 75K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 12m MAX tempCheck on the 12µ MAX temperature. Test passed if the temperature is LT 85K and GT 75K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 12m MIN tempCheck on the 12µ MIN temperature. Test passed if the temperature is LT 85K and GT 75K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 3.7m MAX tempCheck of 3.7µ MAX temp. Test passed if the temperature is LT 85K and GT 75K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of 3.7m MIN tempCheck on 3.7µ MIN temp. Test passed if the temperature is LT 85K and GT 75K. Error setATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of fpp baseplant MAX tempCheck on fpp baseplant MAX temperature.Test passed if the temperature is LT 85K and GT 75K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
SPHAATSR SPH Check of fpp baseplant MIN tempCheck on fpp baseplant MIN temperature. Test passed if the temperature is LT 85K and GT 75K. Error set ATS_TOA_1P; ATS_NR__2P; ATS_AR__2P
ADSAATSR check on packet validation (forward view) number of scans failing CRC checkFails if value not equal 0. Warning set ATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (forward view) number of scans failing basic validationFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (forward view) number of scans null packetFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (forward view) scan error - all other errorsFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (forward view) number of scans showing scan jitterFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (forward view) number of scans showing buffers fullFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) number of scans showing buffers fullFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) number of scans failing CRC checkFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) scan error - all other errorsFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) number of scans showing scan jitterFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) number of scans failing basic validationFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
ADSAATSR check on packet validation (nadir view) number of scans null packetFails if value not equal 0. Warning setATS_TOA_1P; ATS_NR__2P
DSDAATSR check on VC1Fail if sensing start TOA is greater than 7 days wrt the VC1 validity time range. Error set  ATS_TOA_1P